Measures: Temperature, Dew Point, Relative Humidity, Wet Bulb, Air Velocity, Air Volume, Capacity
|
| • |
Lightweight, Easy to Maneuver Measurement Vane
|
| • |
Single Point Average
|
| • |
°C/°F Selectable
|
| • |
Auto Power Off After 10 Minutes of Inactivity
|
| • |
Jumbo Display
|
| • |
Ball Bearing Fan |
| Measurement |
Range |
Resolution |
Accuracy |
| Air Velocity |
0.3 to 35 m/s (1 to 114 ft/s) |
0.1 |
±5% |
| Air Volume |
0 to 99,999 m³/min (0 to 99,999 ft³/min) |
0.1 |
±5% |
| Capacity |
0 to 99,999 BTU/h (0 to 99,999 kW) |
0.1 |
±3% |
| Temperature |
-20 to 60 °C (-4 to 140°F) |
0.1° |
±0.6°C (1°F) |
| Humidity |
0 to 100% |
0.1% |
±3% from 10 to 90% ±5% above 90% |
| Dew Point |
-68 to 70°C (-90 to 158°F) |
0.1° |
±3% from 10 to 90% ±5% above 90% |
| Wet Bulb |
-22 to 70°C (-7.6 to 158°F) |
0.1° |
±3% from 10 to 90% ±5% above 90% | |
|